Connection & Authentication

To control the ALPHA HWR pump, a client must follow a specific connection sequence. Simply connecting via BLE is not enough; the device requires an application-layer handshake to "unlock" control capabilities and high-frequency telemetry.

1. BLE Connection

Advertising

The pump advertises with the Local Name ALPHA_<SERIAL_NUMBER> (e.g., ALPHA_0000479).

Important: The pump advertises its BLE name and manufacturer ID in the advertisement, but NOT the GENI service UUID. The GENI Service UUID is only available in the GATT service table after connection.

  • Device Name: ALPHA_<SERIAL> (advertised, use this to find pump)
  • GENI Service UUID: 0000fdd0-0000-1000-8000-00805f9b34fb (discovered after connecting, NOT in advertisement)
  • Company ID: 0000fe5d-0000-1000-8000-00805f9b34fb (Grundfos manufacturer ID, in service data)

Characteristic

All communication (commands and telemetry) happens over a single GATT Characteristic: * GENI Characteristic: 859cffd1-036e-432a-aa28-1a0085b87ba9 * Properties: Write, Notify

Pairing

The device typically requests Pairing/Bonding upon connection. * Level: Just Works (No PIN usually required, though some models might prompt). * Requirement: Bonding is recommended. While some commands might work without it, stable Schedule downloading (HCI layer) and consistent reconnection often rely on a bonded state.

2. Authentication Handshake ("Unlock")

After connecting and subscribing to notifications, the client must send a specific sequence of "Magic Packets". Without this, the pump may ignore control commands (Start/Stop/Set Mode) and will only stream basic or empty telemetry.

This handshake appears to support both legacy GENI implementations and the newer Class 10 DataObject protocol.

Sequence

The client should send these packets in bursts to ensure the device receives them despite any radio interference or sleep states.

Step A: Legacy Magic Packet (Burst)

Send this packet 3 times with a small delay (~50ms) between writes.

Packet: 27 07 E7 F8 02 03 94 95 96 EB 47

Byte Value Description
0 0x27 Frame Start
1 0x07 Length (Dest + Src + Payload)
2 0xE7 Dest (Service)
3 0xF8 Src (Client)
4 0x02 Class: 2
5 0x03 OpSpec: 0x03 (Length 3)
6-8 94 95 96 Payload (Capabilities/Family Query)
9-10 EB 47 CRC-16

Step B: Class 10 Unlock Packet (Burst)

Send this packet 5 times with a small delay (~50ms) between writes. This appears to be the primary unlock command for modern HWR firmware.

Packet: 27 07 E7 F8 0A 03 56 00 06 C5 5A

Byte Value Description
0 0x27 Frame Start
1 0x07 Length
2 0xE7 Dest
3 0xF8 Src
4 0x0A Class: 10 (DataObject)
5 0x03 OpSpec: 0x03 (Length 3)
6-7 56 00 SubID (Operation/Unlock)
8 0x06 ObjID (Partial/Short)
9-10 C5 5A CRC-16

Step C: Authorization Extend (Sequence)

Send these two packets once each, with a small delay (~100ms) in between.

  1. Packet 1: 27 05 E7 F8 05 C1 4B C3 82
  2. Packet 2: 27 05 E7 F8 0B C1 0F D0 C3

3. Keep-Alive

The pump does not require a strict keep-alive packet if telemetry is streaming. However, if the connection goes idle, the device may disconnect. The library implementation relies on the constant stream of Class 10 telemetry notifications to verify the connection is alive.