Skip to content

Hardware Reference

The Grundfos ALPHA HWR (Hot Water Recirculation) is a smart circulator pump designed for domestic hot water systems with a dedicated return line. It features integrated sensors and Bluetooth connectivity, allowing for app-based control and monitoring.

Models

There are two primary variants of the ALPHA HWR, differentiated mainly by their performance curves (Head/Flow capability).

Feature ALPHA HWR 15-55 ALPHA HWR 15-29
Max Flow Rate (Q) 13.6 GPM (\(3.1 m^3/h\)) 11 GPM (\(2.5 m^3/h\))
Max Head (H) 18 ft (5.5 m) 9.5 ft (2.9 m)
Power Consumption 2 - 38 W 2 - 21 W

Technical Specifications

Parameter Value Notes
Supply Voltage 1 x 115 V, ± 10 %, 60 Hz
Max Outlet Pressure 175 psi (12 bar)
Liquid Temperature 36 - 203 °F (2 - 95 °C) Hard water deposits may occur > 140°F
Ambient Temperature 32 - 131 °F (0 - 55 °C)
Relative Humidity Max 95%
Sound Pressure < 25 dB(A) Silent operation
Pump Housing Stainless Steel
Enclosure Class Type 2 Indoor use only

Alarm & Warning Codes

The pump reports internal error states via the status_code field in the telemetry stream.

Code Error Type Description
51 Blocked Motor The rotor is jammed or blocked by debris.
57 Dry Running The pump detects no water in the housing.
40 Undervoltage Supply voltage is too low.
4 Overvoltage Supply voltage is too high.
35 Air in Media Significant air bubbles detected in the system.
72, 76, 85 Internal Fault Electronics or internal hardware failure.
29 Forced Pumping Water is being forced through the pump by another source.
43 Impellers Forced Impellers are being forced forward.

Hardware Features

Integrated Temperature Sensor

The pump includes an internal sensor that estimates the media temperature. This eliminates the need for an external aquastat in many recirculation setups.

  • Note: The sensor value is available in the telemetry stream as media_temperature_c.

Air Detection & Venting

The ALPHA HWR has a "Continuous Air Detection" feature. If air is detected (Code 35), the pump can run a special venting sequence to push air to the system vent.

Flow Limitation

The pump logic includes safety limits based on pipe diameters to prevent flow-accelerated corrosion. * 1/2" pipes: ~1.5 GPM limit * 3/4" pipes: ~2.3 GPM limit * 1" pipes: ~3.8 GPM limit

Operating Panel vs. Digital Control

The physical operating panel on the pump is limited to selecting three basic modes: 1. AutoAdapt: Temperature control (95-102°F range). 2. Temperature Control: Fixed temp control. 3. Continuous (24/7): Constant Curve III.

Advanced Control: Using the Bluetooth interface unlocks the full range of control modes, including Constant Pressure, Constant Flow, and custom setpoints.