Connection

To control the ALPHA HWR pump, a client bonds over BLE, subscribes to notifications, and then reads and writes GENIbus frames. That is the whole sequence.

Correction, 2026-08-18. This document used to say the device "requires an application-layer handshake to 'unlock' control capabilities and high-frequency telemetry", and described the four packets below as that handshake. Neither claim is supported by any capture in this repository.

The packets decode as ordinary reads — two GETs and two INFO queries — under the GENIbus APDU rule that the second byte is 0booLLLLLL, operation in the top two bits and payload length in the low six. 0x03 is a GET with a 3-byte payload, not a SET, and the "unlock code" was a length field misparsed. Reads cannot change device state, so an unlock was never something these bytes could perform.

A separate client then ran ten connection cycles without sending any of them — including two with the BLE bond cleared and re-paired, and five across pump power cycles. All ten read every Class 7 device-info string and reached full readiness; nine accepted Class 3 START and STOP commands with the motor confirmed running. Across 1,019 captured frames there were no Class 2, Class 5 or Class 11 frames at all.

bench_findings.md, this repository's record of measured rather than inferred behaviour, has never said anything about a handshake requirement. The claim entered in the initial documentation commit, hedged as "may ignore" and "may return ... or fail", which is not how an observation gets written down.

Update, 2026-08-20. The client no longer sends them. Verified on the bench: a bare connect-and-subscribe link, with none of the four packets written, answered all five Class 7 string reads, every Class 10 object read this client makes, and the three telemetry registers. The 750 ms of inter-stage delays went with them — they were transcribed from this client's own sleep() calls and then written up as pump timing requirements.

The packets are still documented below, and kept as constants in alpha_hwr.core.authentication, because they are real captures and make good frame-assembly vectors. See esphome-alpha-hwr issue #174 for the decode and the captures.

1. BLE Connection

Advertising

The pump advertises with the Local Name ALPHA_<SERIAL_NUMBER> (e.g., ALPHA_0000479).

Important: The pump advertises its BLE name and manufacturer ID in the advertisement, but NOT the GENI service UUID. The GENI Service UUID is only available in the GATT service table after connection.

  • Device Name: ALPHA_<SERIAL> (advertised, use this to find pump)
  • GENI Service UUID: 0000fdd0-0000-1000-8000-00805f9b34fb (discovered after connecting, NOT in advertisement)
  • Company ID: 0000fe5d-0000-1000-8000-00805f9b34fb (Grundfos manufacturer ID, in service data)

Characteristic

All communication (commands and telemetry) happens over a single GATT Characteristic: * GENI Characteristic: 859cffd1-036e-432a-aa28-1a0085b87ba9 * Properties: Write, Notify

Pairing

The device requires Pairing/Bonding for normal use. * Level: Just Works (No PIN usually required, though some models might prompt). * Requirement: Bonding is recommended. While some commands might work without it, telemetry, control, stable Schedule downloading (HCI layer), and consistent reconnection are much more reliable after bonding.

2. Opening Reads (optional)

After connecting and subscribing to notifications, this client sends four frames. They are reads, their replies are not consumed, and a pump reaches full readiness and accepts control commands without them. They are retained here as a record of what this client does, not as a requirement.

Sequence

The client should send these packets in bursts to ensure the device receives them despite any radio interference or sleep states.

Step A: Class 2 identity read

A GET of items 148, 149 and 150 — unit_family, unit_type, unit_version. The ALPHA HWR answers 52 / 7 / 2. This client sends it 3 times, ~50ms apart; one send is sufficient, since the reply is the same every time.

Packet: 27 07 E7 F8 02 03 94 95 96 EB 47

Byte Value Description
0 0x27 Frame Start
1 0x07 Length (Dest + Src + Payload)
2 0xE7 Dest (Service)
3 0xF8 Src (Client)
4 0x02 Class: 2
5 0x03 OpSpec: 0x03 (Length 3)
6-8 94 95 96 Payload (Capabilities/Family Query)
9-10 EB 47 CRC-16

Step B: Class 10 operation-status read

A GET of Object 86, Sub 6 — the operation-status object, which answers with the control mode, operation mode and current setpoint. This client sends it 5 times, ~50ms apart. It was described here as "the primary unlock command for modern HWR firmware"; it is a read, and the same object is polled again in normal operation.

Packet: 27 07 E7 F8 0A 03 56 00 06 C5 5A

Byte Value Description
0 0x27 Frame Start
1 0x07 Length
2 0xE7 Dest
3 0xF8 Src
4 0x0A Class: 10 (DataObject)
5 0x03 OpSpec: 0x03 (Length 3)
6 0x56 Object 86
7-8 00 06 Sub 6
9-10 C5 5A CRC-16

Step C: Two INFO queries

INFO asks for a data item's scaling metadata; it reads nothing and changes nothing, which is why "Authorization Extend" was never an accurate name. The pump answers both with a one-byte INFO head meaning "unscaled". Sent once each, ~100ms apart.

  1. Packet 1: 27 05 E7 F8 05 C1 4B C3 82
  2. Packet 2: 27 05 E7 F8 0B C1 0F D0 C3

3. Keep-Alive

The pump does not require a strict keep-alive packet if telemetry is streaming. However, if the connection goes idle, the device may disconnect. The library implementation relies on the constant stream of Class 10 telemetry notifications to verify the connection is alive.