Inputs

Each input has one meaning, defined here, and a name on each surface: the entry in a dataset, the field in Python (Inputs, LiveReading), and the cause named when it cannot be used. Every input is a series.

The names

Input Dataset entry Python Cause
prices prices Inputs.prices prices
PV forecast pv_forecast, or pv_forecast.<array> per array Inputs.pv (a series, or a mapping by array name) pv_forecast
load forecast load_forecast Inputs.load load_forecast
DC-bus load forecast dc_load_forecast Inputs.dc_load load_forecast
SOC soc Inputs.soc, LiveReading.soc battery_soc
dispatch as modelled battery_first Inputs.dispatch_as_modelled, LiveReading.dispatch_as_modelled work_mode
meters each by the plant's meter name Inputs.meters, LiveReading.meters pv_power; a DC-bus load's meter: load_power
house load house Inputs.measured_load, LiveReading.load_kw load_power
heartbeat (optional) heartbeat none: sets known_until, or a client's external cause the client's own
recorded prices (optional) import_price, export_price none none
inverter AC power (optional) inverter none none
the battery's lots none: from the meters, the SOC and the prices Inputs.lots battery_lots

Which command needs which

Command Needs
value prices; the PV forecast (a plant with PV); the load forecast; the SOC and dispatch as modelled (a plant with a battery). A DC-bus load forecast is optional: without one, the command assumes 0 kW and names its own cause, dc_load_forecast, beside the engine's. The battery's lots come from ledger's inputs where the dataset has them; without them, all the battery holds is priced as bought at the import, the valuation names battery_lots, and the command says why on stderr
live value's, and the plant's meters. The house load and a heartbeat are optional: without the house load the live value names load_power; without a heartbeat, nothing judges the telemetry path
replay value's, and the pv, grid and battery meters and the SOC. The prices the battery was charged at are the recorded prices where the dataset has them, else the price forecasts' (below); a heartbeat is optional
ledger the pv, grid and battery meters, the SOC and the prices as replay takes them; a heartbeat is optional
check-plant ledger's, and the house load. The inverter's AC power is optional: without it, the inverter's measures are left out
fit-battery the pv, grid and battery meters, the SOC, the house load and the inverter's AC power

The commands that score against the meters need a plant with a battery and PV.

now, sources and fetch read their inputs from the providers a sources/1 file names instead of a dataset. now gives the engine the battery's lots by running the ledger over the recorded history of the [measured] entities (the two days before now, --lots-run-in); where it cannot, it says why on stderr and the valuation names battery_lots.

Prices

What one more kWh imported costs and one more exported earns, per interval: Price(p_import, p_export). Either may be negative, and the rule carries the sign through: with a negative export price, a kWh that would have spilled earns money when a load uses it, and its price is negative. Any shape works: a flat rate, time-of-use bands, a dynamic price that changes every interval. The currency is yours (Units).

PV forecast

The PV the plant will make, per interval, in kW in its arrays' terms: AC kW for AC-coupled arrays, DC kW for DC-coupled ones. Each value is the forecast's quantiles: any levels between 0 and 1 that include the median (0.5), such as Solcast's 0.1, 0.5 and 0.9, a forecaster's deciles, or the median alone (a point forecast). The scenarios are cut by interpolating between the levels given; beyond the outermost, the outermost step extends on a side that has a level, and the median holds on a side that has none. Quantiles give the price its scenarios; a single value gives one day. A forecast with no level below the median says nothing of the downside: the pessimistic case (marginal_cost_p10) is then the median, and the valuation names pv_spread, its values standing. A plant whose arrays have both couplings takes one forecast per array.

Load forecast

What the house will draw, per interval, in kW: the AC side's loads. A plant with loads on a hybrid's DC bus takes their forecast separately (dc_load_forecast), and the AC forecast then leaves them out.

SOC

The battery's state of charge, as a fraction 0-1 inside the library (a dataset may give percent). A reading more than 0.01 outside 0-1 (one percentage point) is a mistake and cannot be used; within that, it is clamped.

Dispatch as modelled

Whether the plant is running the dispatch its model describes. The plant model describes a self-consumption dispatch: PV serves the house, then charges the battery, then is exported; the battery serves the house before the grid; plus whatever windows plant/2 declares. It is true while the inverter runs that way, and false when it does not: an outside controller drives the battery, or the inverter is in a mode the model does not describe, such as forced charging or backup only. False or unknown makes a valuation fall back, because the model would be predicting a plant that is not running. If your inverter only ever runs one matching mode, a constant true series is right.

The battery's lots

What the battery holds, by source, and what it cost (Lots): the stored kWh from PV, from the grid and of unknown origin, each with its cost, and all of it as one pool whose running average cost prices a kWh the battery delivers (What a stored kWh is worth). A client that keeps the battery's ledger (microgrid.engine.ledger) gives them as a series: each Lots in force from when the ledger booked it. The microgrid command runs the ledger over the dataset's meters itself (The battery's lots), from the first whole slot its meters cover: a moment before that has none; microgrid now runs it over the recorded history before now.

Without lots, everything the battery holds is priced as bought, at the first slot's import price, and a battery valuation or live value on the stored-cost rule names battery_lots in degraded. It stays stored_value_v1: priced at the import, its values are already the conservative ones, so they stand (Missing and stale inputs).

Meters

The plant's own power readings, in kW, each named and signed as plant/2 declares (meters): by default pv, grid (positive importing), battery (positive charging, at its DC side) and, with a DC-bus load, dc_load. The live value reads them for PV now and to tell whether the house is importing; the scoring commands read what the plant did.

House load

What the plant's AC loads draw, as the plant meters it, in kW: the figure many inverters report as home consumption. It is not one of plant/2's meters: those close the plant's balance, and a consumption meter there is an alternative to the grid meter for that. The house load is read on its own: by the live value (what the house draws now) and by check-plant and fit-battery (the load the plant served).

Heartbeat

A series whose samples show the readings were flowing (optional): any series that reports at least every few minutes while the telemetry path is up, such as a meter that reports every few seconds, or a tick the client writes. Its values do not matter; only when its samples arrived. Many recorders store only changes, so a steady SOC and a dead connection look the same in the record; the heartbeat tells them apart. The commands judge the meters unknown once it has been silent longer than the record's limit: --stale-after, else the dataset's limits, else 3 minutes (measured on one plant whose heartbeat reported every few seconds; set your recorder's).

Without a heartbeat, each series is trusted as far as the dataset says it is known (known_until), and a gap in it is a sample with no value. That suits a record you know has no unmarked gaps. If you only have meters that report on change, do not use one as the heartbeat: a quiet meter would read as a dead connection.

Recorded prices

The import and export prices in force, as recorded over time, each a plain series of numbers (optional). The ledger books each kWh charged at them, and replay prices what a kWh realised with them: each slot at the time-weighted mean of the price in force over it, from when each sample says it took effect, so any price interval works on any slot and no price is read before it took effect. Without them, the commands derive them from the price forecasts as received: at each moment, the issue received last that covers it, from its receipt on, as the engine reads prices. A dataset then carries its prices once. Where both are given, the recorded series win: what was in force is what the battery was charged at.

Inverter AC power

The AC power at the battery's converter (its own inverter, or the hybrid it is folded into), positive out to the house (optional). fit-battery reads it to fit the converter's loss; check-plant compares it with the model's, where it is given.