A plant's topology and parameters as plain data: what PlantConfig.from_mapping reads and PlantConfig.to_mapping writes back exactly. The microgrid command reads it from TOML (plant.toml); a Python client may build the mapping from anything. It is the only plant schema. Describe your plant shows how to write one for each topology.

Validation names every problem with its path (battery.capacity_kwh: must be positive), all of them at once: each field's and each part's first, then the rules across parts once the parts are sound. microgrid config check prints them. A key given as null is a key left out; a key the schema does not have is an error.

Units: power kW, energy kWh, SOC a fraction 0-1, wear in the prices' currency per kWh (Currency). Times of day are local, in the plant's zone, written "HH:MM:SS" without an offset.

The top level

Key Required Meaning
schema yes "plant/2"
timezone yes the plant's zone, an IANA name ("Europe/Berlin"); windows are local times in it
pv no a list of arrays; none: a plant without PV
battery no the battery and where it connects; none: a plant without one
hybrid no the hybrid inverter, where the plant has a DC bus
grid no the grid connection's limits
loads no the loads by connection point; default one AC load, house
dispatch no what the plant does on its own beyond self-consumption
meters no the meters the plant reads; default the set below

[[pv]]: an array

Key Default Meaning
name required the array's name; unique, and not a load's
coupling required "ac": its own inverters (micro-inverters, a string inverter) on the AC bus; "dc": strings on a hybrid's DC bus
dc_rating_kw none the MPPT limit, DC kW: it caps the array's DC power
ac_rating_kw none an AC-coupled array's own inverter's rating, AC kW; a DC-coupled array has none

An array's forecast is in its coupling's terms: AC kW for an AC-coupled array, DC kW for a DC-coupled one. A DC-coupled array needs a hybrid.

[battery]

The battery's parameters and its connection, in one table.

Key Default Meaning
capacity_kwh required usable capacity, stored kWh
charge_kw required the charge limit, kW
discharge_kw required the discharge limit, kW
eta_charge 0.94 AC to stored, at low power; in (0.5, 1]
eta_discharge 0.94 stored to AC, at low power; in (0.5, 1]
reserve_soc 0.0 the floor the plant keeps (a backup reserve)
saturation_soc 1.0 where charging counts as full (a BMS that tapers near the top)
wear_charge_per_kwh 0.0 the battery's wear per AC kWh charged; 0 prices cycling as free, so set it (how to estimate)
wear_discharge_per_kwh 0.0 the battery's wear per AC kWh discharged
loss_charge_per_kw 0.0 how the conversion's loss grows with power, charging: kW of loss per (DC kW)², so its unit is 1/kW. At 0.003, charging at 4 kW DC loses 0.003 × 16 = 0.048 kW more than the low-power efficiency says
loss_discharge_per_kw 0.0 the same, discharging
meter_charge 1.0 stored kWh per kWh the battery's meter reads charging; in (0.5, 1.5]
meter_discharge 1.0 stored kWh drawn per kWh the meter reads discharging; in (0.5, 1.5]
connection required "ac": on the AC bus behind its own inverter; "dc_bus": on a hybrid's DC bus
form "folded" on a DC bus: "folded", its conversion one path from the AC bus to stored energy, metered at the DC bus; "split", its conversion the DC bus to stored energy alone, with the hybrid's conversion from the DC bus to AC
inverter none a battery on the AC bus: its own inverter ([battery.inverter], below), required there
dc_charge_kw, dc_discharge_kw none a battery on a DC bus: its own DC limits; a folded battery with anything else on its bus needs them

0 <= reserve_soc < saturation_soc <= 1. With the defaults (no loss growth, a meter that reads stored energy) the conversion is one efficiency each way. microgrid fit-battery fits the efficiencies, the loss growth, the meter factors and the inverter's draws from the meters.

[hybrid] and [battery.inverter]: an inverter

Key Default Meaning
ac_rating_kw none its AC rating, on the net power crossing it
standby_kw 0.0 its own draw, always
working_kw 0.0 its extra draw while the battery works through it
working_threshold_kw 0.05 the battery works above this, kW either way
conversion none the hybrid's DC bus to AC ([hybrid.conversion]): required where no folded battery holds it, refused where one does; never on a battery's own inverter

[hybrid.conversion]:

Key Default Meaning
eta_in required AC to DC bus, at low power; in (0, 1]
eta_out required DC bus to AC, at low power; in (0, 1]
loss_in_per_kw, loss_out_per_kw 0.0 loss growth each way, kW of loss per (DC kW)² (unit 1/kW)

A folded battery with anything else on its DC bus (DC PV, a DC load) needs the hybrid's ac_rating_kw and its own dc_charge_kw and dc_discharge_kw, and must not store more per DC kWh than it draws (meter_charge <= meter_discharge).

[grid]

Key Default Meaning
import_limit_kw none the most the site can import
export_limit_kw none the most it may export; 0: it may not export

[[loads]]

Key Default Meaning
name required the load's name, unique
connection "ac" "ac", or "dc_bus": on a hybrid's DC bus

At least one load is on the AC bus: the house. A DC-bus load needs a hybrid. The load forecast owns every load's kW; the plant only says where each connects. The names are labels: the engine takes the loads by connection point, all the AC loads' forecast as one series (Inputs.load) and the DC-bus loads' as another (Inputs.dc_load), never by name (the plant model knows connection points, not load names). A name is checked unique and read by nothing else; it says, for a reader of the file, which load is which.

[dispatch]

Key Default Meaning
grid_charge none the grid-charge windows (below)
export_windows none the battery-export windows (below)
charge_order "pv_first" in a grid-charge window, "pv_first": the grid tops up only what the PV still to come in the window will not; "target_first": the grid tops up as the target needs, not counting that PV. PV still charges first within a slot either way
hold_rules none when the plant holds its battery through a DC-bus load's session (below)

[[dispatch.grid_charge]]: a grid-charge window

Inside the window the grid tops the battery up to a target that PV alone would not reach by end.

Key Default Meaning
start, end required local times; the window lies within one local day (start before end)
target_soc 1.0 the target; above the battery's reserve
cover_until none a target from need: what the house will draw from end until this time (net of PV and of discharge losses), when that is lower than target_soc; at or before end means the next day; not inside the window
timing "early" "early": from the window's start, as soon as PV will fall short; "late": only what the rest of the window could no longer add at the charge limit, so the top-up comes as late as it can

No two windows overlap, grid-charge or export.

[[dispatch.export_windows]]: a battery-export window

The plant discharging the battery to the grid.

Key Default Meaning
start, end required local times, within one day
power_kw required AC kW, held through the window; within the battery's discharge limit, its inverter's rating and the grid's export limit
floor_soc required the window stops at this SOC, at or above the reserve and below saturation
yields "pv" which yields at the export limit: "pv" or "battery"

[[dispatch.hold_rules]]: holding through a DC-bus load's session

While the DC-bus loads draw more than dc_load_above_kw, a session that starts with the SOC below start_below_soc keeps the battery from discharging until it ends.

Key Meaning
dc_load_above_kw a session is the DC-bus loads drawing more than this, DC kW
start_below_soc the SOC a session must start below to hold the battery; above the reserve

A hold rule needs a battery and a DC-bus load.

[[meters]]

The meters the plant reads, each by name. A live reading and a dataset key each meter's kW by its name.

Key Default Meaning
name required unique
measures required "pv", "grid", "battery", "consumption" or "dc_load". consumption is the AC loads and the inverters' draw, metered in place of the grid; it is not the dataset's house load
array none a PV meter: the array it meters; none: every array together (only where they share one coupling)
at none a battery meter: "dc" (its DC side, the default) or "ac" (its own inverter's AC side, for a battery on the AC bus only). fit-battery reads the battery's meter as DC
sign 1 1 where positive is PV made, importing, charging or drawing; -1 where it is the opposite

The set must close the plant's balance: the grid or the consumption metered (one gives the other), the battery where there is one, the DC-bus loads where there are any, and every array's PV, each or together.

The default set, without meters: pv for every array together (with arrays of both couplings, one per array named pv:<array>, which a dataset cannot name: name them yourself to record them), grid, battery at its DC side where there is a battery, and dc_load where a load is on the DC bus, each with sign 1.

Examples

The library ships four example plants (microgrid.plant.examples), each with synthetic, round parameters fitted to no real plant.

schema = "plant/2"
timezone = "Europe/Berlin"

[[pv]]
name = "roof"
coupling = "ac"

[battery]
capacity_kwh = 12.0
charge_kw = 6.0
discharge_kw = 6.0
eta_charge = 0.96
eta_discharge = 0.96
reserve_soc = 0.1
wear_charge_per_kwh = 0.02
wear_discharge_per_kwh = 0.02
loss_charge_per_kw = 0.003
loss_discharge_per_kw = 0.003
meter_charge = 0.99
meter_discharge = 1.0
connection = "dc_bus"
form = "folded"

[hybrid]
standby_kw = 0.03
working_kw = 0.06

[[dispatch.grid_charge]]
start = "01:00:00"
end = "05:00:00"
target_soc = 0.6
timing = "late"
schema = "plant/2"
timezone = "Europe/Berlin"

[[pv]]
name = "strings"
coupling = "dc"
dc_rating_kw = 8.0

[battery]
capacity_kwh = 10.0
charge_kw = 5.0
discharge_kw = 5.0
eta_charge = 0.98
eta_discharge = 0.98
reserve_soc = 0.1
wear_charge_per_kwh = 0.02
wear_discharge_per_kwh = 0.02
connection = "dc_bus"
form = "split"

[hybrid]
ac_rating_kw = 6.0
standby_kw = 0.03
working_kw = 0.04

[hybrid.conversion]
eta_in = 0.97
eta_out = 0.97
loss_in_per_kw = 0.002
loss_out_per_kw = 0.002

[grid]
export_limit_kw = 5.0

[[dispatch.grid_charge]]
start = "02:00:00"
end = "05:00:00"
target_soc = 0.5
schema = "plant/2"
timezone = "Europe/Berlin"

[[pv]]
name = "east"
coupling = "ac"
dc_rating_kw = 3.5
ac_rating_kw = 3.0

[[pv]]
name = "west"
coupling = "ac"
dc_rating_kw = 3.5
ac_rating_kw = 3.0
schema = "plant/2"
timezone = "Europe/Berlin"

[battery]
capacity_kwh = 13.5
charge_kw = 5.0
discharge_kw = 5.0
eta_charge = 0.95
eta_discharge = 0.95
reserve_soc = 0.2
wear_charge_per_kwh = 0.03
wear_discharge_per_kwh = 0.03
connection = "ac"

[battery.inverter]
ac_rating_kw = 5.0
standby_kw = 0.03
working_kw = 0.03

[[dispatch.grid_charge]]
start = "00:00:00"
end = "05:00:00"
target_soc = 0.9

[[dispatch.export_windows]]
start = "17:00:00"
end = "20:00:00"
power_kw = 3.0
floor_soc = 0.3