A plant model is only worth pricing with if what it projects is what the plant does. microgrid check-plant feeds the model what actually happened (the metered PV, the load the plant served, the metered SOC at the start), so no forecast error is in the way, and compares its projection with the meters.

What it needs

A dataset with, for the days to check, the plant's pv, grid and battery meters, the SOC, the house load and the prices (recorded, or the price forecasts'), and optionally a heartbeat (Inputs). The plant needs PV and a battery: the command reads both meters, and without a battery there is nothing to project.

Run it

uv run microgrid check-plant --data examples/dataset --from 2026-10-21 --to 2026-10-26

The days are local, --to included. It runs the model two ways:

  • From each local midnight, for the day: the day's import and export, how far the SOC strays, and when the battery tops up, first fills and first runs empty.
  • From each hour, over 48 hours: the SOC's error by hours ahead, and whether the model's first event (fill, top-up, empty) is the meters' first event.

Read it

plant model against the meters, 2026-10-21 .. 2026-10-26 (Europe/Berlin)
day         import kWh m/r   export kWh m/r   SOC MAE/max pp  top-up m|r     full m|r       reasons
2026-10-21    3.2 /   3.2    13.4 /  13.4     0.0 /   0.0   04:40|04:40  11:40|11:40  -
...
over 6 days without a telemetry gap (model - meters):
  import kWh/day         bias  +0.000  MAE  0.000
  export kWh/day         bias  +0.000  MAE  0.000
  ...
  SOC by hours ahead, MAE/max: 0-1h 0.0/0.8 pp (n 870), 1-3h 0.0/0.8 pp (n 1722), ...
  first event agreed in 135 of 138 hourly runs

routing, model -> meters (slots):
  battery serving -> battery serving   387
  PV charging -> PV charging           170
  ...
  • m/r is the model, then the meters (recorded).
  • The day table: each day's import and export, the SOC's mean and largest error in percentage points, and the times of the top-up and of the first full battery. A day the telemetry was silent is labelled and left out of the summary.
  • The summary: each measure's bias (model minus meters) and mean absolute error over the days, and the median gap between the model's event times and the meters'.
  • SOC by hours ahead: how the error grows over the 48-hour runs. The price rule looks that far ahead, so this is the error the prices carry from the plant model.
  • First event agreed: in how many hourly runs the model's first fill, top-up or empty was the meters' first. A fill bounds a battery kWh's price, and when the battery charges sets what it holds, so this is the measure closest to the price.
  • Routing: slot by slot, what the model said served the house against what the meters said.

The example dataset was made by the plant model itself, so it agrees with itself almost everywhere. Your plant's will not, and the differences say what to fix.

What to do with the result

  • Large SOC errors from midnight: the battery's parameters. Fit its conversion (Fit the battery's conversion) and check capacity_kwh and reserve_soc.
  • Top-up times or amounts off: the grid-charge window in plant/2 (its target, cover_until and timing).
  • Import or export off by a steady amount: a load the plant serves that the house meter does not see, or the inverter's own draw (standby_kw, working_kw).
  • A topology that does not fit at all: see Describe your plant, or write your own plant model.

Try a candidate without changing the dataset's file: --plant candidate.toml.

The command reports measures; it does not pass or fail a plant. Which days a model is not meant to describe (a day the plant was serviced, a day it ran another mode), and the pass marks a model must meet before you trust its prices, are yours to add.