The ledger keeps track of where the energy in the battery came from and what it cost: its lots, and all of it as one pool. It answers "what does the battery hold, from which source, at what cost per kWh?". The price reads the pool: a kWh the battery delivers costs the pool's running average, through the discharge's loss and wear (What a stored kWh is worth).

Lots and the pool

The ledger keeps the same energy two ways:

  • The lots, by source: PV, the grid, and energy of unknown origin, each with its cost. They say what the battery's energy is made of, and they set the floor below. To book a discharge they must take it from some lot first, in an order (below).
  • The pool: all the battery holds, and what it cost, as one. Charging adds to it at cost; a discharge takes energy at its average, so its average does not move. The price reads it.

Both hold the same energy and are scaled to the same meter. They differ only in what a discharge takes: the lots, the energy of the lot drawn first; the pool, the average. The order lots are drawn in is a convention, and a price that followed it would move with the convention, not with anything the battery did. So the price reads the pool.

The lots still matter:

  • The cost split of the stored energy: what the battery holds by source, and what a client publishes about it.
  • A guard for a scheduler that does not model the battery. The cost of the next kWh drawn (floor_per_kwh) is a sanity floor, never the price: a controller that treated the basis of a single lot as the price would strand grid-charged energy whenever prices fell.

How a lot is booked

A lot is a source (PV, the grid, or unknown), an amount of stored energy (the battery's side of the inverter), and a cost basis per stored kWh.

Charging. Charging c AC kWh at price p stores c × η_c kWh at a basis of p / η_c per stored kWh. The price is what the site gave up for it:

  • a PV lot at the export price when it was charged (the export the site gave up to store it);
  • a grid lot at the import price.

The price is the recorded price in force over the slot, its time-weighted mean, from when each sample says it took effect: any price interval works on any slot, and no price counts before it took effect. A dataset with no recorded prices is charged at those its price forecasts put in force, as received (Recorded prices).

Discharging. Delivering d AC kWh draws d / η_d stored kWh, and the value drawn is the delivery's cost, the conversion loss included.

Order. Energy of unknown origin is drawn first, by the house and by exports alike. After it, the house is served from grid lots before PV lots, and exports come from PV lots before grid lots: grid energy can go to only one destination, PV energy to either, so drawing the restricted lots first keeps the remaining inventory worth the most. Within a source, lots are a weighted average.

Unknown energy. What the battery held when the ledger started, or what the meter shows when the model held nothing, has no known cost. In the lots it is kept apart at no value, reported as such, and never sets the floor. In the pool it is priced as bought, at the import: the ledger's first slot's for what it held when it began, the slot's for energy the meter finds. The price needs a cost for every kWh the battery delivers, and not knowing what one cost moves it toward the import (Energy of unknown origin).

The meter wins

After each slot the lots, and the pool, are scaled to the metered stored energy, both ways and pro rata at their own basis. What the model does not explain (self-discharge, the battery management system, meter timing, an efficiency slightly off) shows as unexplained, never as drift and never as free energy.

Flows at the meters' resolution

The ledger reads the metered powers at every change of any of them, not as 10-minute means. A 10-minute net mean blurs two states into one: when a DC-bus load's session starts, the battery can swing from charging on PV to discharging into the load, and the mean looks like the grid charging the battery. Only stretches where the telemetry path was alive count (a heartbeat, series.alive); a slot with any silent stretch moves nothing, and the meter catches it up.

Efficiencies

The battery's meter reads DC; it is converted to AC with the battery's fitted conversion, whose loss grows with power. A charge is booked by the path it took, as the plant model works it out from the metered AC (Storage.stored_per_kwh): PV and the grid charge through the same inverter on an AC-coupled plant, so they share it, and a grid top-up loses more only because it runs at the charge limit; on a hybrid's DC bus the AC crosses the hybrid and DC PV does not.

Using it

microgrid ledger runs the ledger over a span of a dataset and prints, by source, what was charged and at what cost, what went to the house and to export, what is held at the end and its cost per kWh, and the unexplained energy. See Read the battery's lots. microgrid value, live and replay run the same ledger over the dataset's meters and give the engine its lots at each moment; microgrid now runs it over the two days of recorded history before now.

From Python, microgrid.engine.ledger (API): a Ledger stepped slot by slot, its held lots and its pool, and Lots(as_of, held, pool) to hand the engine as Inputs.lots (Inputs).