Slots and the horizon

A slot is the unit of time the engine prices: 10 minutes by default (engine/2's slot_minutes). Slots are counted from the epoch in UTC, so every slot starts on the same grid whatever the time zone: 13:00, 13:10, 13:20 UTC. The slot length must divide an hour.

The horizon is how far a valuation reaches: 48 hours by default (horizon_hours), from the slot under way. A valuation at 13:04 starts with the slot 13:00-13:10, of which 6 minutes remain; that first slot is valued for the time left in it.

Where the horizon stops short

The horizon ends at the first slot an input cannot fill:

  • the prices: past the last priced interval;
  • the PV forecast: past the forecast's end;
  • the load forecast: past its end. A gap inside it (a slot unknown with known slots after it) also cuts the horizon there, and the valuation says so with horizon_cut.

So a valuation can have fewer slots than 48 hours' worth. In the example dataset the load forecast received by 11:00 UTC on 2026-10-22 ends at 10:30 UTC two days later, so a valuation at 11:00 UTC (13:00 local) has 285 slots, not 288.

Why fixed slots

  • One grid for every input. A forecast's intervals are aligned onto the slots: an hourly price holds over six 10-minute slots; two 5-minute prices average into one. An interval that crosses a slot's edge without covering the slot (15-minute prices over 10-minute slots) is refused, not stretched: prices so are unpriced, naming prices; choose a slot they tile (slot_minutes = 15, or 5). Every command, the scoring and the ledger among them, works on the engine's slot. See Series and forecasts.
  • The noise floors are for 10-minute slots. The default thresholds below which a metered flow is not an event were measured on 10-minute means (observed). Another slot length may need others.

A day

Where a rule needs "a day", it means 24 hours of slots: the certainty that the battery covers the expensive hours compares prices with the cheapest import in the 24 hours from the slot, and the horizon rule uses the horizon's last 24 hours.

Times are UTC inside

The engine refuses a time that is not UTC. Python compares and subtracts two aware times that share a time zone by wall clock, which is wrong across a daylight-saving change. So a client converts at its edge, and the engine never sees local time. The one exception is the plant's own clock: grid-charge and export windows are local times in the zone plant/2 names, because that is how a plant's settings are written.