Scope

The library models the plant and produces marginal prices. Its inputs come from the client, its prices go to the client, and what the client does with them is the client's.

What a client brings

The library needs Where it comes from
import and export prices, per interval any source of prices, or a file
a PV forecast, with quantiles or a single value any solar forecast, or a file
a load forecast any forecast of the house's load, or a file
the battery's SOC and the meters the plant's own monitoring, a recorder, a file
the plant's topology (plant/2) you, once

Each is a series (Inputs). None of the sources is assumed: a sources/1 file names a provider per input, or a client hands the series over from a dataset or Python.

What it can't model

  • Tariffs beyond a per-kWh price. Prices are an import and an export price per kWh, per interval. Demand charges, standing charges, tiered or block rates and netting over a billing period are not modelled, because none of them is a price on one more kWh in one slot. A standing charge does not change with use, so it never affects a marginal price. A demand charge prices the peak kW over a billing period, which a price per kWh cannot express; at most a client can raise the import price in hours it expects a new peak, an approximation of its own.
  • A plant run by an outside optimiser or controller. The plant model describes the plant's own self-consumption rules. When something else drives the battery, the plant is not running as modelled, and every valuation falls back to the import price. To price such a plant, run it in a mode the model describes, or write a plant model that projects what your controller will do.
  • Topologies checked against real meters: one. The plant model has been checked against one real plant's meters: AC-coupled PV with a battery on a hybrid's DC bus and a load on that bus. Every other topology plant/2 accepts runs through the same dispatch but has not yet been checked; check yours.

Prices energy, models no load

No load's run is priced, and none is taken out of the house load: the load is the plant's metered consumption, as it is. A load on the plant's DC bus is in the plant model only as topology: where it connects.

No I/O

The library fetches nothing, publishes nothing and stores nothing, so the same inputs give the same answer wherever it runs, and a replay at a past moment is exactly what a live client would have computed then. The microgrid command and any service that publishes prices are clients of it.